Bekrić, Dragoljub

Link to this page

Authority KeyName Variants
6b65a9c5-00db-4d2c-bd70-74cad339bd26
  • Bekrić, Dragoljub (2)
Projects
No records found.

Author's Bibliography

Determination of the ductile-to-brittle transition temperature of NIOMOL 490 K steel welded joints

Maksimović, Ana; Milović, Ljubica; Zečević, Bojana; Aleksić, Vujadin; Bekrić, Dragoljub

(Elsevier, 2024)

TY  - JOUR
AU  - Maksimović, Ana
AU  - Milović, Ljubica
AU  - Zečević, Bojana
AU  - Aleksić, Vujadin
AU  - Bekrić, Dragoljub
PY  - 2024
UR  - http://rims.institutims.rs/handle/123456789/861
AB  - This paper is dedicated to the ductile–brittle transition behaviour of the microalloyed structural steel NIOMOL 490 K. This steel grade is used for welded pressure vessels subjected to dynamic loads and operating at sub-zero temperatures. Therefore, it must have an acceptable toughness. Due to its importance for the safety assessment of pressure vessels, a characterization of this steel was carried out using the Charpy V-notch impact test in the temperature range between - 60 ◦C and + 60 ◦C. The notches were located in parent material, heat affected zone
and weld metal. In this paper, the tensile strength properties at ambient temperature and the nil ductility temperature in the temperature range from - 60 ◦C to + 60 ◦C are presented.
PB  - Elsevier
T2  - Theoretical and Applied Fracture Mechanics
T1  - Determination of the ductile-to-brittle transition temperature of NIOMOL 490 K steel welded joints
IS  - 104404
VL  - 131
DO  - 10.1016/j.tafmec.2024.104404
ER  - 
@article{
author = "Maksimović, Ana and Milović, Ljubica and Zečević, Bojana and Aleksić, Vujadin and Bekrić, Dragoljub",
year = "2024",
abstract = "This paper is dedicated to the ductile–brittle transition behaviour of the microalloyed structural steel NIOMOL 490 K. This steel grade is used for welded pressure vessels subjected to dynamic loads and operating at sub-zero temperatures. Therefore, it must have an acceptable toughness. Due to its importance for the safety assessment of pressure vessels, a characterization of this steel was carried out using the Charpy V-notch impact test in the temperature range between - 60 ◦C and + 60 ◦C. The notches were located in parent material, heat affected zone
and weld metal. In this paper, the tensile strength properties at ambient temperature and the nil ductility temperature in the temperature range from - 60 ◦C to + 60 ◦C are presented.",
publisher = "Elsevier",
journal = "Theoretical and Applied Fracture Mechanics",
title = "Determination of the ductile-to-brittle transition temperature of NIOMOL 490 K steel welded joints",
number = "104404",
volume = "131",
doi = "10.1016/j.tafmec.2024.104404"
}
Maksimović, A., Milović, L., Zečević, B., Aleksić, V.,& Bekrić, D.. (2024). Determination of the ductile-to-brittle transition temperature of NIOMOL 490 K steel welded joints. in Theoretical and Applied Fracture Mechanics
Elsevier., 131(104404).
https://doi.org/10.1016/j.tafmec.2024.104404
Maksimović A, Milović L, Zečević B, Aleksić V, Bekrić D. Determination of the ductile-to-brittle transition temperature of NIOMOL 490 K steel welded joints. in Theoretical and Applied Fracture Mechanics. 2024;131(104404).
doi:10.1016/j.tafmec.2024.104404 .
Maksimović, Ana, Milović, Ljubica, Zečević, Bojana, Aleksić, Vujadin, Bekrić, Dragoljub, "Determination of the ductile-to-brittle transition temperature of NIOMOL 490 K steel welded joints" in Theoretical and Applied Fracture Mechanics, 131, no. 104404 (2024),
https://doi.org/10.1016/j.tafmec.2024.104404 . .

Experimental Determination of JIc for a HSLA Steel Welded Joint

Maksimović, Ana; Petrovski, Blagoj; Milović, Ljubica; Zečević, Bojana; Aleksić, Vujadin; Bulatović, Srđan; Bekrić, Dragoljub

(Elsevier B.V., 2023)

TY  - JOUR
AU  - Maksimović, Ana
AU  - Petrovski, Blagoj
AU  - Milović, Ljubica
AU  - Zečević, Bojana
AU  - Aleksić, Vujadin
AU  - Bulatović, Srđan
AU  - Bekrić, Dragoljub
PY  - 2023
UR  - http://rims.institutims.rs/handle/123456789/660
AB  - Most serious weldment failures have catastrophic consequences in terms of damage to other equipment, loss of production, and risks to worker health and safety. For the above reasons, there is a tendency to find the line between safety and disaster, and this requires a guarantee of the integrity of the welded structure even if a crack is present. The structural and mechanical heterogeneity of a welded joint affects its resistance to cracking in both the elastic and plastic regions. Therefore, it is important to define the test method and the position of the fatigue crack. The behavior of an elasto-plastic material, during stable crack growth can be described by the J-Δa diagram. As the crack propagates, a point on the curve is defined, which represents the critical value of the J-integral. The aim of this experiment is to determine JIC value and the procedure is reflected in the determination of the R-curve, i.e., the J‒Δa curve, which consists of the value of the J-integral for uniform crack increments Δa. In this paper, precracked SEN(B) specimens with the fatigue crack positioned in the weld metal (WM) were tested according to standard ASTM E1820 at room temperature (RT), -20 °C and -30 °C.
PB  - Elsevier B.V.
T2  - Procedia Structural Integrity
T1  - Experimental Determination of JIc for a HSLA Steel Welded Joint
EP  - 194
SP  - 190
VL  - 48
DO  - 10.1016/j.prostr.2023.07.147
ER  - 
@article{
author = "Maksimović, Ana and Petrovski, Blagoj and Milović, Ljubica and Zečević, Bojana and Aleksić, Vujadin and Bulatović, Srđan and Bekrić, Dragoljub",
year = "2023",
abstract = "Most serious weldment failures have catastrophic consequences in terms of damage to other equipment, loss of production, and risks to worker health and safety. For the above reasons, there is a tendency to find the line between safety and disaster, and this requires a guarantee of the integrity of the welded structure even if a crack is present. The structural and mechanical heterogeneity of a welded joint affects its resistance to cracking in both the elastic and plastic regions. Therefore, it is important to define the test method and the position of the fatigue crack. The behavior of an elasto-plastic material, during stable crack growth can be described by the J-Δa diagram. As the crack propagates, a point on the curve is defined, which represents the critical value of the J-integral. The aim of this experiment is to determine JIC value and the procedure is reflected in the determination of the R-curve, i.e., the J‒Δa curve, which consists of the value of the J-integral for uniform crack increments Δa. In this paper, precracked SEN(B) specimens with the fatigue crack positioned in the weld metal (WM) were tested according to standard ASTM E1820 at room temperature (RT), -20 °C and -30 °C.",
publisher = "Elsevier B.V.",
journal = "Procedia Structural Integrity",
title = "Experimental Determination of JIc for a HSLA Steel Welded Joint",
pages = "194-190",
volume = "48",
doi = "10.1016/j.prostr.2023.07.147"
}
Maksimović, A., Petrovski, B., Milović, L., Zečević, B., Aleksić, V., Bulatović, S.,& Bekrić, D.. (2023). Experimental Determination of JIc for a HSLA Steel Welded Joint. in Procedia Structural Integrity
Elsevier B.V.., 48, 190-194.
https://doi.org/10.1016/j.prostr.2023.07.147
Maksimović A, Petrovski B, Milović L, Zečević B, Aleksić V, Bulatović S, Bekrić D. Experimental Determination of JIc for a HSLA Steel Welded Joint. in Procedia Structural Integrity. 2023;48:190-194.
doi:10.1016/j.prostr.2023.07.147 .
Maksimović, Ana, Petrovski, Blagoj, Milović, Ljubica, Zečević, Bojana, Aleksić, Vujadin, Bulatović, Srđan, Bekrić, Dragoljub, "Experimental Determination of JIc for a HSLA Steel Welded Joint" in Procedia Structural Integrity, 48 (2023):190-194,
https://doi.org/10.1016/j.prostr.2023.07.147 . .