Fire resistance testing of fire doors

Ilić, Snežana; Laban, Mirjana; Džolev, Igor

(2022)

TY  - CONF
AU  - Ilić, Snežana
AU  - Laban, Mirjana
AU  - Džolev, Igor
PY  - 2022
UR  - http://rims.institutims.rs/handle/123456789/603
AB  - Fire-resistant doors are widely used as part of passive fire protection systems, preventing the spread of fire and smoke beyond the fire compartment. Fire resistance is usually determined through standard fire tests in accredited laboratories, such as the Laboratory for thermal technique and fire protection in Institute IMS, Serbia. Current regulations in Serbia allow testing of fire doors according to two standards: Serbian national SRPS U.J1.160 [1] and European SRPS EN 1634-1 [2].
In the past five years, 236 samples of different fire doors were tested. Most of them were single-leaf, steel doors. Although almost one third (31%) of all samples (tested on 15, 20, 30, 45, 60, 90, 120, 180, 240 and 380 minutes) provided fire resistance of 120 minutes, which should be sufficient for the safe evacuation of people, as well as the protection of expensive equipment (hospitals, rooms with electrical devices, etc.).Samples usually fail the test when sustained flaming occurs on the unexposed side in the upper corner of the specimen (lock side), or when the temperature measured by thermocouples exceeds the limitation given in the standard, usually at the top corner (lock side).In this paper, both currently valid standard testing procedures are analysed and compared.
C3  - 8 th INTERNATIONAL SCIENTIFIC CONFERENCE SAFETY ENGINEERING CONFERENCE WITH INTERNATIONAL PARTICIPATION ON FIRE AND EXPLOSION PROTECTION Budva, Montenegro, BOOK OF PROCEEDINGS
T1  - Fire resistance testing of fire doors
UR  - https://hdl.handle.net/21.15107/rcub_rims_603
ER  - 
@conference{
author = "Ilić, Snežana and Laban, Mirjana and Džolev, Igor",
year = "2022",
abstract = "Fire-resistant doors are widely used as part of passive fire protection systems, preventing the spread of fire and smoke beyond the fire compartment. Fire resistance is usually determined through standard fire tests in accredited laboratories, such as the Laboratory for thermal technique and fire protection in Institute IMS, Serbia. Current regulations in Serbia allow testing of fire doors according to two standards: Serbian national SRPS U.J1.160 [1] and European SRPS EN 1634-1 [2].
In the past five years, 236 samples of different fire doors were tested. Most of them were single-leaf, steel doors. Although almost one third (31%) of all samples (tested on 15, 20, 30, 45, 60, 90, 120, 180, 240 and 380 minutes) provided fire resistance of 120 minutes, which should be sufficient for the safe evacuation of people, as well as the protection of expensive equipment (hospitals, rooms with electrical devices, etc.).Samples usually fail the test when sustained flaming occurs on the unexposed side in the upper corner of the specimen (lock side), or when the temperature measured by thermocouples exceeds the limitation given in the standard, usually at the top corner (lock side).In this paper, both currently valid standard testing procedures are analysed and compared.",
journal = "8 th INTERNATIONAL SCIENTIFIC CONFERENCE SAFETY ENGINEERING CONFERENCE WITH INTERNATIONAL PARTICIPATION ON FIRE AND EXPLOSION PROTECTION Budva, Montenegro, BOOK OF PROCEEDINGS",
title = "Fire resistance testing of fire doors",
url = "https://hdl.handle.net/21.15107/rcub_rims_603"
}
Ilić, S., Laban, M.,& Džolev, I.. (2022). Fire resistance testing of fire doors. in 8 th INTERNATIONAL SCIENTIFIC CONFERENCE SAFETY ENGINEERING CONFERENCE WITH INTERNATIONAL PARTICIPATION ON FIRE AND EXPLOSION PROTECTION Budva, Montenegro, BOOK OF PROCEEDINGS.
https://hdl.handle.net/21.15107/rcub_rims_603
Ilić S, Laban M, Džolev I. Fire resistance testing of fire doors. in 8 th INTERNATIONAL SCIENTIFIC CONFERENCE SAFETY ENGINEERING CONFERENCE WITH INTERNATIONAL PARTICIPATION ON FIRE AND EXPLOSION PROTECTION Budva, Montenegro, BOOK OF PROCEEDINGS. 2022;.
https://hdl.handle.net/21.15107/rcub_rims_603 .
Ilić, Snežana, Laban, Mirjana, Džolev, Igor, "Fire resistance testing of fire doors" in 8 th INTERNATIONAL SCIENTIFIC CONFERENCE SAFETY ENGINEERING CONFERENCE WITH INTERNATIONAL PARTICIPATION ON FIRE AND EXPLOSION PROTECTION Budva, Montenegro, BOOK OF PROCEEDINGS (2022),
https://hdl.handle.net/21.15107/rcub_rims_603 .

Testing of building materials - reaction to fire

Ilić, Snežana; Mirković-Marjanović, Milica; Kijanović, Aleksandar; Laban, Mirjana

(2022)

TY  - CONF
AU  - Ilić, Snežana
AU  - Mirković-Marjanović, Milica
AU  - Kijanović, Aleksandar
AU  - Laban, Mirjana
PY  - 2022
UR  - http://rims.institutims.rs/handle/123456789/441
AB  - To reduce occurrence of fires in buildings as efficiently as possible, it is necessary to take into account active and passive fire protection measures during construction of building. This paper will show more about passive fire protection measures related to the selection of adequate material to be used during construction, which contributes to the localization of fire and prevents it from spreading to other rooms and facilities.
All products, which are planned by project, must have adequate certificates not to contribute to the development of fire, as well as to meet the class of fire resistance. In the Republic of Serbia, only the Laboratory for Thermal Engineering and Fire Protection, within the IMS Institute, deals with this type of testing and issuing reports.
This paper will present test methods for obtaining a fire reaction class. After the tests, according to the standard SRPS EN 13501-1, a Classification Report is issued in which the final fire reaction class is given for the tested product whose validity lasts for 5 years.
C3  - Proceedings of the 17th Conference with International participation risk and safety engineering, Kopaonik
T1  - Testing of building materials - reaction to fire
EP  - 119
SP  - 111
UR  - https://hdl.handle.net/21.15107/rcub_rims_441
ER  - 
@conference{
author = "Ilić, Snežana and Mirković-Marjanović, Milica and Kijanović, Aleksandar and Laban, Mirjana",
year = "2022",
abstract = "To reduce occurrence of fires in buildings as efficiently as possible, it is necessary to take into account active and passive fire protection measures during construction of building. This paper will show more about passive fire protection measures related to the selection of adequate material to be used during construction, which contributes to the localization of fire and prevents it from spreading to other rooms and facilities.
All products, which are planned by project, must have adequate certificates not to contribute to the development of fire, as well as to meet the class of fire resistance. In the Republic of Serbia, only the Laboratory for Thermal Engineering and Fire Protection, within the IMS Institute, deals with this type of testing and issuing reports.
This paper will present test methods for obtaining a fire reaction class. After the tests, according to the standard SRPS EN 13501-1, a Classification Report is issued in which the final fire reaction class is given for the tested product whose validity lasts for 5 years.",
journal = "Proceedings of the 17th Conference with International participation risk and safety engineering, Kopaonik",
title = "Testing of building materials - reaction to fire",
pages = "119-111",
url = "https://hdl.handle.net/21.15107/rcub_rims_441"
}
Ilić, S., Mirković-Marjanović, M., Kijanović, A.,& Laban, M.. (2022). Testing of building materials - reaction to fire. in Proceedings of the 17th Conference with International participation risk and safety engineering, Kopaonik, 111-119.
https://hdl.handle.net/21.15107/rcub_rims_441
Ilić S, Mirković-Marjanović M, Kijanović A, Laban M. Testing of building materials - reaction to fire. in Proceedings of the 17th Conference with International participation risk and safety engineering, Kopaonik. 2022;:111-119.
https://hdl.handle.net/21.15107/rcub_rims_441 .
Ilić, Snežana, Mirković-Marjanović, Milica, Kijanović, Aleksandar, Laban, Mirjana, "Testing of building materials - reaction to fire" in Proceedings of the 17th Conference with International participation risk and safety engineering, Kopaonik (2022):111-119,
https://hdl.handle.net/21.15107/rcub_rims_441 .

Determination of ventilation heat losses through building envelope – a case study

Ilić, Snežana; Malešev, Mirjana; Mirković-Marjanović, Milica; Kijanović, Aleksandar

(University of Banja Luka Faculty of Architecture, Civil Engineering and Geodesy, 2022)

TY  - CONF
AU  - Ilić, Snežana
AU  - Malešev, Mirjana
AU  - Mirković-Marjanović, Milica
AU  - Kijanović, Aleksandar
PY  - 2022
UR  - http://rims.institutims.rs/handle/123456789/438
AB  - In this paper the experimental procedure for the determination of ventilation heat losses across building envelopes has been shown. The alternative name for this method is Blower Door Test or Fan Pressurization method. This text is a user manual for the determination of ventilation heat losses and parameters which is used to describe the air permeability of buildings. The experiment examination was performed at the office with old and after with new windows. The results were compared, and a significant contribution of new windows was shown.
PB  - University of Banja Luka Faculty of Architecture, Civil Engineering and Geodesy
C3  - Proceedings of International conference on contemporary theory and practice in construction XV, STEPGRAD 2022
T1  - Determination of ventilation heat losses through building envelope – a case study
EP  - 558
SP  - 552
UR  - https://hdl.handle.net/21.15107/rcub_rims_438
ER  - 
@conference{
author = "Ilić, Snežana and Malešev, Mirjana and Mirković-Marjanović, Milica and Kijanović, Aleksandar",
year = "2022",
abstract = "In this paper the experimental procedure for the determination of ventilation heat losses across building envelopes has been shown. The alternative name for this method is Blower Door Test or Fan Pressurization method. This text is a user manual for the determination of ventilation heat losses and parameters which is used to describe the air permeability of buildings. The experiment examination was performed at the office with old and after with new windows. The results were compared, and a significant contribution of new windows was shown.",
publisher = "University of Banja Luka Faculty of Architecture, Civil Engineering and Geodesy",
journal = "Proceedings of International conference on contemporary theory and practice in construction XV, STEPGRAD 2022",
title = "Determination of ventilation heat losses through building envelope – a case study",
pages = "558-552",
url = "https://hdl.handle.net/21.15107/rcub_rims_438"
}
Ilić, S., Malešev, M., Mirković-Marjanović, M.,& Kijanović, A.. (2022). Determination of ventilation heat losses through building envelope – a case study. in Proceedings of International conference on contemporary theory and practice in construction XV, STEPGRAD 2022
University of Banja Luka Faculty of Architecture, Civil Engineering and Geodesy., 552-558.
https://hdl.handle.net/21.15107/rcub_rims_438
Ilić S, Malešev M, Mirković-Marjanović M, Kijanović A. Determination of ventilation heat losses through building envelope – a case study. in Proceedings of International conference on contemporary theory and practice in construction XV, STEPGRAD 2022. 2022;:552-558.
https://hdl.handle.net/21.15107/rcub_rims_438 .
Ilić, Snežana, Malešev, Mirjana, Mirković-Marjanović, Milica, Kijanović, Aleksandar, "Determination of ventilation heat losses through building envelope – a case study" in Proceedings of International conference on contemporary theory and practice in construction XV, STEPGRAD 2022 (2022):552-558,
https://hdl.handle.net/21.15107/rcub_rims_438 .

European and national assessment procedure for the fire performance of facades

Laban, Mirjana; Ilić, Snežana; Džolev, Igor; Draganić, Suzana

(2022)

TY  - CONF
AU  - Laban, Mirjana
AU  - Ilić, Snežana
AU  - Džolev, Igor
AU  - Draganić, Suzana
PY  - 2022
UR  - http://rims.institutims.rs/handle/123456789/439
AB  - Innovative construction systems, increasing use of combustible material in facades, less and less space between buildings, increased energy requirements; the transformation of facades in response to these changes requires the involvement of fire safety experts. nts at Grenfell Tower,
London and The Address in Dubai have demonstrated, use of combustible façade elements and lack of-quick time, primarily through the façade. We need to learn from these disasters. Other
incidents prove that the use of nonsuppression.
In the past years EU experts are working on development of common method for assessment of the fire performance of façade systems. The classification system should be transparent and should fit within the framework of existing national regulations. The common assessment method should be applicable to the wide range of façades systems available in the market including glazed façades, green façades and other emerging technologies.
There is a progress in developing legislation on façade fire safety in non-EU countries, due to
emerging fire safety problems and harmonization of regulation with EU. Fire safety of facades in
Serbia is defined through several rulebooks and standards, which significantly improved requirements.
This paper presents the comparative analysis of legislation on facade fire safety in Serbia and other European countries.
C3  - Proceedings of the 19th International Symposium MASE, Ohrid, 2022
T1  - European and national assessment procedure for the fire performance of facades
EP  - 582
SP  - 577
UR  - https://hdl.handle.net/21.15107/rcub_rims_439
ER  - 
@conference{
author = "Laban, Mirjana and Ilić, Snežana and Džolev, Igor and Draganić, Suzana",
year = "2022",
abstract = "Innovative construction systems, increasing use of combustible material in facades, less and less space between buildings, increased energy requirements; the transformation of facades in response to these changes requires the involvement of fire safety experts. nts at Grenfell Tower,
London and The Address in Dubai have demonstrated, use of combustible façade elements and lack of-quick time, primarily through the façade. We need to learn from these disasters. Other
incidents prove that the use of nonsuppression.
In the past years EU experts are working on development of common method for assessment of the fire performance of façade systems. The classification system should be transparent and should fit within the framework of existing national regulations. The common assessment method should be applicable to the wide range of façades systems available in the market including glazed façades, green façades and other emerging technologies.
There is a progress in developing legislation on façade fire safety in non-EU countries, due to
emerging fire safety problems and harmonization of regulation with EU. Fire safety of facades in
Serbia is defined through several rulebooks and standards, which significantly improved requirements.
This paper presents the comparative analysis of legislation on facade fire safety in Serbia and other European countries.",
journal = "Proceedings of the 19th International Symposium MASE, Ohrid, 2022",
title = "European and national assessment procedure for the fire performance of facades",
pages = "582-577",
url = "https://hdl.handle.net/21.15107/rcub_rims_439"
}
Laban, M., Ilić, S., Džolev, I.,& Draganić, S.. (2022). European and national assessment procedure for the fire performance of facades. in Proceedings of the 19th International Symposium MASE, Ohrid, 2022, 577-582.
https://hdl.handle.net/21.15107/rcub_rims_439
Laban M, Ilić S, Džolev I, Draganić S. European and national assessment procedure for the fire performance of facades. in Proceedings of the 19th International Symposium MASE, Ohrid, 2022. 2022;:577-582.
https://hdl.handle.net/21.15107/rcub_rims_439 .
Laban, Mirjana, Ilić, Snežana, Džolev, Igor, Draganić, Suzana, "European and national assessment procedure for the fire performance of facades" in Proceedings of the 19th International Symposium MASE, Ohrid, 2022 (2022):577-582,
https://hdl.handle.net/21.15107/rcub_rims_439 .

Komparativna analiza ispitivanja požarnootpornih vrata prema srpskim standardima

Ilić, Snežana; Popović, Ljiljana; Ćosić, Đorđe

(Departman za građevinarstvo i geodeziju, Fakultet tehničkih nauka, Novi Sad, 2021)

TY  - CONF
AU  - Ilić, Snežana
AU  - Popović, Ljiljana
AU  - Ćosić, Đorđe
PY  - 2021
UR  - http://rims.institutims.rs/handle/123456789/442
AB  - Prilikom zaštite zgrada od požara neophodno je podeliti objekte na požarne sektore.
Kako ne bi došlo do prenosa vatre iz jednog požarnog sektora u drugi, potrebno je ugraditi
požarnootporna vrata. Sva ugrađena požarnootporna vrata moraju da poseduju dokaz o
otpornosti prema požaru, čija se vrednost dobija ispitivanjem u akreditovanoj laboratoriji.
Ispitivanje može da se izvrši prema dva standarda: SRPS U.J1.160 iz 1988. godine, kao i SRPS
EN 1634-1 iz 2018. godine.
U radu je predstavljena komparativna analiza između dva standarda u kojima su dati uslovi u
peći, način ugradnje uzorka, oprema koja se koristi za ispitivanje, kao i vrednost za otpornost
prema požaru. Standard SRPS EN 1634-1 mnogo detaljnije opisuje način ugradnje, postavljane
termoparova, proces ispitivanja, kao i vrednost za otpornost prema požaru u odnosu kako je to
dato u SRPS U.J1.160.
PB  - Departman za građevinarstvo i geodeziju, Fakultet tehničkih nauka, Novi Sad
C3  - Zbornik radova- 15. međunarodna naučna konferencija „Planiranje projektovanje, građenje i obnova graditeljstva iNDiS 2021“, Novi Sad
T1  - Komparativna analiza ispitivanja požarnootpornih vrata prema srpskim standardima
EP  - 1027
SP  - 1020
UR  - https://hdl.handle.net/21.15107/rcub_rims_442
ER  - 
@conference{
author = "Ilić, Snežana and Popović, Ljiljana and Ćosić, Đorđe",
year = "2021",
abstract = "Prilikom zaštite zgrada od požara neophodno je podeliti objekte na požarne sektore.
Kako ne bi došlo do prenosa vatre iz jednog požarnog sektora u drugi, potrebno je ugraditi
požarnootporna vrata. Sva ugrađena požarnootporna vrata moraju da poseduju dokaz o
otpornosti prema požaru, čija se vrednost dobija ispitivanjem u akreditovanoj laboratoriji.
Ispitivanje može da se izvrši prema dva standarda: SRPS U.J1.160 iz 1988. godine, kao i SRPS
EN 1634-1 iz 2018. godine.
U radu je predstavljena komparativna analiza između dva standarda u kojima su dati uslovi u
peći, način ugradnje uzorka, oprema koja se koristi za ispitivanje, kao i vrednost za otpornost
prema požaru. Standard SRPS EN 1634-1 mnogo detaljnije opisuje način ugradnje, postavljane
termoparova, proces ispitivanja, kao i vrednost za otpornost prema požaru u odnosu kako je to
dato u SRPS U.J1.160.",
publisher = "Departman za građevinarstvo i geodeziju, Fakultet tehničkih nauka, Novi Sad",
journal = "Zbornik radova- 15. međunarodna naučna konferencija „Planiranje projektovanje, građenje i obnova graditeljstva iNDiS 2021“, Novi Sad",
title = "Komparativna analiza ispitivanja požarnootpornih vrata prema srpskim standardima",
pages = "1027-1020",
url = "https://hdl.handle.net/21.15107/rcub_rims_442"
}
Ilić, S., Popović, L.,& Ćosić, Đ.. (2021). Komparativna analiza ispitivanja požarnootpornih vrata prema srpskim standardima. in Zbornik radova- 15. međunarodna naučna konferencija „Planiranje projektovanje, građenje i obnova graditeljstva iNDiS 2021“, Novi Sad
Departman za građevinarstvo i geodeziju, Fakultet tehničkih nauka, Novi Sad., 1020-1027.
https://hdl.handle.net/21.15107/rcub_rims_442
Ilić S, Popović L, Ćosić Đ. Komparativna analiza ispitivanja požarnootpornih vrata prema srpskim standardima. in Zbornik radova- 15. međunarodna naučna konferencija „Planiranje projektovanje, građenje i obnova graditeljstva iNDiS 2021“, Novi Sad. 2021;:1020-1027.
https://hdl.handle.net/21.15107/rcub_rims_442 .
Ilić, Snežana, Popović, Ljiljana, Ćosić, Đorđe, "Komparativna analiza ispitivanja požarnootpornih vrata prema srpskim standardima" in Zbornik radova- 15. međunarodna naučna konferencija „Planiranje projektovanje, građenje i obnova graditeljstva iNDiS 2021“, Novi Sad (2021):1020-1027,
https://hdl.handle.net/21.15107/rcub_rims_442 .

Comparative analysis of current standards for testing thermal protection of facade carpentry

Ilić, Snežana; Kijanović, Aleksandar; Laban, Mirjana

(Regional Association for Security and Crisis Management-RASEC S4 GLOSEC Global Security, 2021)

TY  - CONF
AU  - Ilić, Snežana
AU  - Kijanović, Aleksandar
AU  - Laban, Mirjana
PY  - 2021
UR  - http://rims.institutims.rs/handle/123456789/437
AB  - The low level of energy efficiency in buildings results in increased energy
consumption for heating and cooling and high carbon dioxide emissions. Insufficient
thermal protection of the exterior of a building contributes to a high value of thermal
transmittance of external walls and facade carpentry.
Regulations and standards in the field of energy efficiency in Serbia are going to be
harmonized with European documents, which is an integral part of the EU accession
process. Before placing construction products on the market, it is necessary to examine
product performances of products so that the thermal transmittance of facade carpentry
can be tested according two valid Serbian standards: SRPS U.J5. 060 from 1984 and
SRPS EN ISO 12567-1, which were adopted in 2012. These types of testing can only be
performed in accredited laboratories.
The paper presents a comparative analysis of those two standards for testing thermal
transmittance of external carpentry, the testing method, measuring equipment, the
obtaining of results that prove the performance of the product.
PB  - Regional Association for Security and Crisis Management-RASEC S4 GLOSEC Global Security
C3  - Proceedings of the “Safety for the future 2021 security and crisis management -theory and practice”, Belgrade
T1  - Comparative analysis of current standards for testing thermal protection of facade carpentry
EP  - 223
SP  - 215
UR  - https://hdl.handle.net/21.15107/rcub_rims_437
ER  - 
@conference{
author = "Ilić, Snežana and Kijanović, Aleksandar and Laban, Mirjana",
year = "2021",
abstract = "The low level of energy efficiency in buildings results in increased energy
consumption for heating and cooling and high carbon dioxide emissions. Insufficient
thermal protection of the exterior of a building contributes to a high value of thermal
transmittance of external walls and facade carpentry.
Regulations and standards in the field of energy efficiency in Serbia are going to be
harmonized with European documents, which is an integral part of the EU accession
process. Before placing construction products on the market, it is necessary to examine
product performances of products so that the thermal transmittance of facade carpentry
can be tested according two valid Serbian standards: SRPS U.J5. 060 from 1984 and
SRPS EN ISO 12567-1, which were adopted in 2012. These types of testing can only be
performed in accredited laboratories.
The paper presents a comparative analysis of those two standards for testing thermal
transmittance of external carpentry, the testing method, measuring equipment, the
obtaining of results that prove the performance of the product.",
publisher = "Regional Association for Security and Crisis Management-RASEC S4 GLOSEC Global Security",
journal = "Proceedings of the “Safety for the future 2021 security and crisis management -theory and practice”, Belgrade",
title = "Comparative analysis of current standards for testing thermal protection of facade carpentry",
pages = "223-215",
url = "https://hdl.handle.net/21.15107/rcub_rims_437"
}
Ilić, S., Kijanović, A.,& Laban, M.. (2021). Comparative analysis of current standards for testing thermal protection of facade carpentry. in Proceedings of the “Safety for the future 2021 security and crisis management -theory and practice”, Belgrade
Regional Association for Security and Crisis Management-RASEC S4 GLOSEC Global Security., 215-223.
https://hdl.handle.net/21.15107/rcub_rims_437
Ilić S, Kijanović A, Laban M. Comparative analysis of current standards for testing thermal protection of facade carpentry. in Proceedings of the “Safety for the future 2021 security and crisis management -theory and practice”, Belgrade. 2021;:215-223.
https://hdl.handle.net/21.15107/rcub_rims_437 .
Ilić, Snežana, Kijanović, Aleksandar, Laban, Mirjana, "Comparative analysis of current standards for testing thermal protection of facade carpentry" in Proceedings of the “Safety for the future 2021 security and crisis management -theory and practice”, Belgrade (2021):215-223,
https://hdl.handle.net/21.15107/rcub_rims_437 .

Fire protection of health facilities

Ilić, Snežana; Radonjanin, Vlastimir; Laban, Mirjana; Bukvić, Olivera

(2021)

TY  - CONF
AU  - Ilić, Snežana
AU  - Radonjanin, Vlastimir
AU  - Laban, Mirjana
AU  - Bukvić, Olivera
PY  - 2021
UR  - http://rims.institutims.rs/handle/123456789/440
AB  - Critical infrastructure can be demaged, destroyed or disrupted by deliberate acts of natural disasters,negligence, terrorism, sccidents or computer hacking, criminal activity and malicious behaviour. When it comes to the protection of critical infrastructure, one of the most important branches which requires protection is the health system.
In the Republic of Serbia, there are no specific technical rules that deal with the fire protection for construction of health facilities. The Rulebook on the protection of residential, business and public buildings from fire partly mentions hospital facilities. Due to the lack of domestic laes designers must rely on foreign laws and regulations.
The paper presents active and passive fire protection that needs to be implemented when designing health facilities and an example of laws used in other countries relating to the fire protection of hospitals.
In addition to active and passive protection of medical facilities buildings it is also necessary to continuously educate both staff and patients to prevent panic attacks and mistakes that may occur due to an inadequate response.
C3  - Proceedings of the the 17th International Conference on fire and explosion protection and the 7th International Scientific Conference on safety engineering – fire, environment, work environment, integrated risks, Kladovo
T1  - Fire protection of health facilities
UR  - https://hdl.handle.net/21.15107/rcub_rims_440
ER  - 
@conference{
author = "Ilić, Snežana and Radonjanin, Vlastimir and Laban, Mirjana and Bukvić, Olivera",
year = "2021",
abstract = "Critical infrastructure can be demaged, destroyed or disrupted by deliberate acts of natural disasters,negligence, terrorism, sccidents or computer hacking, criminal activity and malicious behaviour. When it comes to the protection of critical infrastructure, one of the most important branches which requires protection is the health system.
In the Republic of Serbia, there are no specific technical rules that deal with the fire protection for construction of health facilities. The Rulebook on the protection of residential, business and public buildings from fire partly mentions hospital facilities. Due to the lack of domestic laes designers must rely on foreign laws and regulations.
The paper presents active and passive fire protection that needs to be implemented when designing health facilities and an example of laws used in other countries relating to the fire protection of hospitals.
In addition to active and passive protection of medical facilities buildings it is also necessary to continuously educate both staff and patients to prevent panic attacks and mistakes that may occur due to an inadequate response.",
journal = "Proceedings of the the 17th International Conference on fire and explosion protection and the 7th International Scientific Conference on safety engineering – fire, environment, work environment, integrated risks, Kladovo",
title = "Fire protection of health facilities",
url = "https://hdl.handle.net/21.15107/rcub_rims_440"
}
Ilić, S., Radonjanin, V., Laban, M.,& Bukvić, O.. (2021). Fire protection of health facilities. in Proceedings of the the 17th International Conference on fire and explosion protection and the 7th International Scientific Conference on safety engineering – fire, environment, work environment, integrated risks, Kladovo.
https://hdl.handle.net/21.15107/rcub_rims_440
Ilić S, Radonjanin V, Laban M, Bukvić O. Fire protection of health facilities. in Proceedings of the the 17th International Conference on fire and explosion protection and the 7th International Scientific Conference on safety engineering – fire, environment, work environment, integrated risks, Kladovo. 2021;.
https://hdl.handle.net/21.15107/rcub_rims_440 .
Ilić, Snežana, Radonjanin, Vlastimir, Laban, Mirjana, Bukvić, Olivera, "Fire protection of health facilities" in Proceedings of the the 17th International Conference on fire and explosion protection and the 7th International Scientific Conference on safety engineering – fire, environment, work environment, integrated risks, Kladovo (2021),
https://hdl.handle.net/21.15107/rcub_rims_440 .