Strength of the Welded Joint with Improved Mechanical Properties of Weld Metal and Heat Affected Zone
(Faculty of Mechanical and Civil Engineering in Kraljevo, University of Kragujevac, Vrnjačka Banja, 2021)
Selection of steel, dimensions and fabrication technology for the welded structure are all parts of the design
process, because they are in close connection with the function of the structural whole under certain conditions ...
Properties of concrete kerbs with recycled aggregate from precast elements
(ZAG, Ljubljana, 2021)
The paper presents the possibility of using recycled aggregate from precast concrete paving elements
and kerbs in the production of concrete kerb units. Experimental work included several types of concrete consistency
class ...
Repair of shaft and ventilation ring vanes damages of the generator of the hydroelectric generating set at the hydro power plant
(Savez energetičara, 2020)
Hydro power plant ’Pirot’, which was built in 1990, is
an accumulation-derivative power plant, which consists of 2
above-ground vertical hydroelectric generating sets that contain
Francis turbines with nominal power of ...
Welded Joints Integrity of the Pressure Vessels Pipes Made of Hot Rolled Fine-Grained Steel
(Savez energetičara, 2021)
This paper contains results of tests performed in order
to determine mechanical properties of steel P460NL1, meant for
production of pressure vessels. Arc welding of samples from
which the specimens were taken was carried ...
Effect of temperature and specimen orientation on Charpy impact toughness
(Elsevier, 2022)
Steel grade 14MoV6 3 is used for manufacturing of boilers and steam pipelines designed for steam temperatures up to 560°C. This paper presents the experimental analysis which included impact toughness test. The analysis ...
Lamellar Tearing of Parent Material and Degradation of Welded Joints at Vital Welded Structures
(Savez energetičara, 2021)
Vertical Kaplan turbines, manufactured in Russia, are
installed in 6 hydroelectric generating units at ‘Djerdap 1’, with
nominal power of 176 MW each. Because of the structural
solution and inability of performing ...