Effect of locally damaged elbow segments on the integrity and reliability of the heating system
(Institut za ispitivanje materijala, Beograd, 2016)
This paper presents the integrity and reliability evaluation of the heating system as a whole, based on results of metallographic tests performed on parent material and the ultrasonic measurement of wall thickness of elbows ...
Probabilistic analysis of bearing capacity of piles with variable parameters in cpt test and calculation according to the requirements
(Institut za ispitivanje materijala, Beograd, 2016)
A probabilistic concept for determining pile bearing capacity is presented, taking into account the variability of CPT test parameters and methodology of calculation according to the requirements of Eurocode 7 (EN 1997-1: ...
Integrity assessment of regulation system pipeline elements in hydroelectric generating set a6 of hydro power plant 'djerdap 1'
(Institut za ispitivanje materijala, Beograd, 2016)
Vertical Kaplan turbines with nominal power of 176 MW manufactured in Russia are installed in 6 hydroelectric generating sets at hydro power plant 'Djerdap 1' (Kladovo, Serbia). Most of the components are made of materials ...
Determination of damage and repair methodology for the runner manhole of Kaplan turbine at the hydro power plant 'Djerdap 1'
(Institut za ispitivanje materijala, Beograd, 2016)
Results of non-destructive testing of the Kaplan turbine runner manhole welded structure are presented, on the basis of which the repair methodology is defined. During repair, the welding technology for elements of the ...