Integrity assessment of regulation system pipeline elements in hydroelectric generating set a6 of hydro power plant 'djerdap 1'

Thumbnail
2016
300.pdf (526.8Kb)
Authors
Međo, Bojan
Arsić, Miodrag
Rakin, Marko
Sedmak, Simon
Malešević, Zoranka
Savić, Zoran
Article (Published version)
Metadata
Show full item record
Abstract
Vertical Kaplan turbines with nominal power of 176 MW manufactured in Russia are installed in 6 hydroelectric generating sets at hydro power plant 'Djerdap 1' (Kladovo, Serbia). Most of the components are made of materials in accordance to GOST and ASTM standards. During rehabilitation of hydroelectric generating set, the analysis of the current state and integrity assessment of turbine regulation system pipeline required non-destructive tests on parent material and welded joints between pipes and pipes-elbows. The purpose of the regulation system, comprising of the pipeline for the turbine regulator oil supply, is to open and close vanes of the guide vane apparatus and to regulate the position of runner blades and their number of revolutions. Internal pressure in the regulation system is p = 4 MPa. Structural integrity is a recent scientific and engineering discipline which in broader sense comprises state analysis and behaviour diagnostics, service life assessment and rehabilitation ...of structures, meaning that beside the usual situation where structural integrity assessment is required when flaws are detected by non-destructive testing, this discipline is also includes stress state analysis. This approach is especially important for welded structures, since cracktype flaws can originate from welding and from unfavourable service conditions. In this paper, the results of non-destructive tests referring to the lack of penetration in roots of butt-welded joints between pipes and pipes-elbows, as well as tensile test results of technical specimens with reinforcements and in specimens with parallel machined sides and standard dimensions, are presented in order to carry out the integrity assessment of the turbine regulation system pipeline of hydroelectric generating set A6 at hydro power plant Djerdap 1. Results of analytical strength calculation of butt-welded joints between 2 pipes, and pipe-elbow with a lack of penetration in the root are also presented.

Keywords:
Welded joint / Strength calculation / Pipeline integrity
Source:
Structural Integrity and Life, 2016, 16, 2, 71-78
Publisher:
  • Institut za ispitivanje materijala, Beograd

ISSN: 1451-3749

Scopus: 2-s2.0-85008158293
[ Google Scholar ]
1
Handle
https://hdl.handle.net/21.15107/rcub_technorep_3159
URI
http://rims.institutims.rs/handle/123456789/303
Collections
  • Radovi istraživača / Researchers' publications
Institution/Community
Institut za ispitivanje materijala
TY  - JOUR
AU  - Međo, Bojan
AU  - Arsić, Miodrag
AU  - Rakin, Marko
AU  - Sedmak, Simon
AU  - Malešević, Zoranka
AU  - Savić, Zoran
PY  - 2016
UR  - http://rims.institutims.rs/handle/123456789/303
AB  - Vertical Kaplan turbines with nominal power of 176 MW manufactured in Russia are installed in 6 hydroelectric generating sets at hydro power plant 'Djerdap 1' (Kladovo, Serbia). Most of the components are made of materials in accordance to GOST and ASTM standards. During rehabilitation of hydroelectric generating set, the analysis of the current state and integrity assessment of turbine regulation system pipeline required non-destructive tests on parent material and welded joints between pipes and pipes-elbows. The purpose of the regulation system, comprising of the pipeline for the turbine regulator oil supply, is to open and close vanes of the guide vane apparatus and to regulate the position of runner blades and their number of revolutions. Internal pressure in the regulation system is p = 4 MPa. Structural integrity is a recent scientific and engineering discipline which in broader sense comprises state analysis and behaviour diagnostics, service life assessment and rehabilitation of structures, meaning that beside the usual situation where structural integrity assessment is required when flaws are detected by non-destructive testing, this discipline is also includes stress state analysis. This approach is especially important for welded structures, since cracktype flaws can originate from welding and from unfavourable service conditions. In this paper, the results of non-destructive tests referring to the lack of penetration in roots of butt-welded joints between pipes and pipes-elbows, as well as tensile test results of technical specimens with reinforcements and in specimens with parallel machined sides and standard dimensions, are presented in order to carry out the integrity assessment of the turbine regulation system pipeline of hydroelectric generating set A6 at hydro power plant Djerdap 1. Results of analytical strength calculation of butt-welded joints between 2 pipes, and pipe-elbow with a lack of penetration in the root are also presented.
PB  - Institut za ispitivanje materijala, Beograd
T2  - Structural Integrity and Life
T1  - Integrity assessment of regulation system pipeline elements in hydroelectric generating set a6 of hydro power plant 'djerdap 1'
EP  - 78
IS  - 2
SP  - 71
VL  - 16
UR  - https://hdl.handle.net/21.15107/rcub_technorep_3159
ER  - 
@article{
author = "Međo, Bojan and Arsić, Miodrag and Rakin, Marko and Sedmak, Simon and Malešević, Zoranka and Savić, Zoran",
year = "2016",
abstract = "Vertical Kaplan turbines with nominal power of 176 MW manufactured in Russia are installed in 6 hydroelectric generating sets at hydro power plant 'Djerdap 1' (Kladovo, Serbia). Most of the components are made of materials in accordance to GOST and ASTM standards. During rehabilitation of hydroelectric generating set, the analysis of the current state and integrity assessment of turbine regulation system pipeline required non-destructive tests on parent material and welded joints between pipes and pipes-elbows. The purpose of the regulation system, comprising of the pipeline for the turbine regulator oil supply, is to open and close vanes of the guide vane apparatus and to regulate the position of runner blades and their number of revolutions. Internal pressure in the regulation system is p = 4 MPa. Structural integrity is a recent scientific and engineering discipline which in broader sense comprises state analysis and behaviour diagnostics, service life assessment and rehabilitation of structures, meaning that beside the usual situation where structural integrity assessment is required when flaws are detected by non-destructive testing, this discipline is also includes stress state analysis. This approach is especially important for welded structures, since cracktype flaws can originate from welding and from unfavourable service conditions. In this paper, the results of non-destructive tests referring to the lack of penetration in roots of butt-welded joints between pipes and pipes-elbows, as well as tensile test results of technical specimens with reinforcements and in specimens with parallel machined sides and standard dimensions, are presented in order to carry out the integrity assessment of the turbine regulation system pipeline of hydroelectric generating set A6 at hydro power plant Djerdap 1. Results of analytical strength calculation of butt-welded joints between 2 pipes, and pipe-elbow with a lack of penetration in the root are also presented.",
publisher = "Institut za ispitivanje materijala, Beograd",
journal = "Structural Integrity and Life",
title = "Integrity assessment of regulation system pipeline elements in hydroelectric generating set a6 of hydro power plant 'djerdap 1'",
pages = "78-71",
number = "2",
volume = "16",
url = "https://hdl.handle.net/21.15107/rcub_technorep_3159"
}
Međo, B., Arsić, M., Rakin, M., Sedmak, S., Malešević, Z.,& Savić, Z.. (2016). Integrity assessment of regulation system pipeline elements in hydroelectric generating set a6 of hydro power plant 'djerdap 1'. in Structural Integrity and Life
Institut za ispitivanje materijala, Beograd., 16(2), 71-78.
https://hdl.handle.net/21.15107/rcub_technorep_3159
Međo B, Arsić M, Rakin M, Sedmak S, Malešević Z, Savić Z. Integrity assessment of regulation system pipeline elements in hydroelectric generating set a6 of hydro power plant 'djerdap 1'. in Structural Integrity and Life. 2016;16(2):71-78.
https://hdl.handle.net/21.15107/rcub_technorep_3159 .
Međo, Bojan, Arsić, Miodrag, Rakin, Marko, Sedmak, Simon, Malešević, Zoranka, Savić, Zoran, "Integrity assessment of regulation system pipeline elements in hydroelectric generating set a6 of hydro power plant 'djerdap 1'" in Structural Integrity and Life, 16, no. 2 (2016):71-78,
https://hdl.handle.net/21.15107/rcub_technorep_3159 .

DSpace software copyright © 2002-2015  DuraSpace
About RIMS | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About RIMS | Send Feedback

OpenAIRERCUB