Electro-filter ash use in the underground coal mines

Thumbnail
2017
317.pdf (449.5Kb)
Authors
Todorović, Vladimir
Dragosavljević, Zlatko
Dramlić, Dejan
Branković, Boban
Article (Published version)
Metadata
Show full item record
Abstract
Thermal power plants in the Republic of Serbia spend 35-40 million tons of coal annually, mostly lignite, with about 6 million tons of ash or slag as a by-product of electricity and heat production, deposited on the landfills. The Law on Waste Management defines the possibility of reusing of ash and slag. The Rulebook on categories, testing and classification of waste, as well as the Decree on technical and other requirements for ash, as building material intended for use in the construction, reconstruction, rehabilitation and maintenance of infrastructure facilities of public purpose, electro-filter ash and slag are characterized as the non-hazardous waste for a wide range of use. In recent decades, the electro-filter ash has been used in several fields in the coal mines, increasingly gaining in importance, and what is the subject of this work in order to demonstrate the efficiency of its use and at the same time contribute to the environmental protection.
Keywords:
mines / fire insulation / electro-filter ash / coal
Source:
Mining and Metallurgy Engineering Bor, 2017, 1-2, 143-148
Publisher:
  • Institut za rudarstvo i metalurgiju, Bor

DOI: 10.5937/mmeb1702143T

ISSN: 2334-8836

[ Google Scholar ]
URI
http://rims.institutims.rs/handle/123456789/320
Collections
  • Radovi istraživača / Researchers' publications
Institution/Community
Institut za ispitivanje materijala
TY  - JOUR
AU  - Todorović, Vladimir
AU  - Dragosavljević, Zlatko
AU  - Dramlić, Dejan
AU  - Branković, Boban
PY  - 2017
UR  - http://rims.institutims.rs/handle/123456789/320
AB  - Thermal power plants in the Republic of Serbia spend 35-40 million tons of coal annually, mostly lignite, with about 6 million tons of ash or slag as a by-product of electricity and heat production, deposited on the landfills. The Law on Waste Management defines the possibility of reusing of ash and slag. The Rulebook on categories, testing and classification of waste, as well as the Decree on technical and other requirements for ash, as building material intended for use in the construction, reconstruction, rehabilitation and maintenance of infrastructure facilities of public purpose, electro-filter ash and slag are characterized as the non-hazardous waste for a wide range of use. In recent decades, the electro-filter ash has been used in several fields in the coal mines, increasingly gaining in importance, and what is the subject of this work in order to demonstrate the efficiency of its use and at the same time contribute to the environmental protection.
PB  - Institut za rudarstvo i metalurgiju, Bor
T2  - Mining and Metallurgy Engineering Bor
T1  - Electro-filter ash use in the underground coal mines
EP  - 148
IS  - 1-2
SP  - 143
DO  - 10.5937/mmeb1702143T
ER  - 
@article{
author = "Todorović, Vladimir and Dragosavljević, Zlatko and Dramlić, Dejan and Branković, Boban",
year = "2017",
abstract = "Thermal power plants in the Republic of Serbia spend 35-40 million tons of coal annually, mostly lignite, with about 6 million tons of ash or slag as a by-product of electricity and heat production, deposited on the landfills. The Law on Waste Management defines the possibility of reusing of ash and slag. The Rulebook on categories, testing and classification of waste, as well as the Decree on technical and other requirements for ash, as building material intended for use in the construction, reconstruction, rehabilitation and maintenance of infrastructure facilities of public purpose, electro-filter ash and slag are characterized as the non-hazardous waste for a wide range of use. In recent decades, the electro-filter ash has been used in several fields in the coal mines, increasingly gaining in importance, and what is the subject of this work in order to demonstrate the efficiency of its use and at the same time contribute to the environmental protection.",
publisher = "Institut za rudarstvo i metalurgiju, Bor",
journal = "Mining and Metallurgy Engineering Bor",
title = "Electro-filter ash use in the underground coal mines",
pages = "148-143",
number = "1-2",
doi = "10.5937/mmeb1702143T"
}
Todorović, V., Dragosavljević, Z., Dramlić, D.,& Branković, B.. (2017). Electro-filter ash use in the underground coal mines. in Mining and Metallurgy Engineering Bor
Institut za rudarstvo i metalurgiju, Bor.(1-2), 143-148.
https://doi.org/10.5937/mmeb1702143T
Todorović V, Dragosavljević Z, Dramlić D, Branković B. Electro-filter ash use in the underground coal mines. in Mining and Metallurgy Engineering Bor. 2017;(1-2):143-148.
doi:10.5937/mmeb1702143T .
Todorović, Vladimir, Dragosavljević, Zlatko, Dramlić, Dejan, Branković, Boban, "Electro-filter ash use in the underground coal mines" in Mining and Metallurgy Engineering Bor, no. 1-2 (2017):143-148,
https://doi.org/10.5937/mmeb1702143T . .