Analysis of current state and strength evaluation of the pipeline at hydro power plant 'Pirot'

dc.creatorArsić, Miodrag
dc.creatorGrabulov, Vencislav
dc.creatorMladenović, Mladen
dc.creatorSavić, Zoran
dc.date.accessioned2022-04-18T15:18:42Z
dc.date.available2022-04-18T15:18:42Z
dc.date.issued2018
dc.identifier.issn0354-7965
dc.identifier.urihttp://rims.institutims.rs/handle/123456789/339
dc.description.abstractHidroelektrana Pirot, koja je izgrađena 1990 godine, je akumulaciona elektrana derivacionog tipa, koja se sastoji od dva nadzemna vertikalna agregata sa Francis turbinama nominalne snage 41,5 MW, proizvedene u Češkoj Republici, tunela i ukopanog cevovoda ukupne dužine 2030 m i prečnika od O 3000 mm do O 3500 mm. Cevovod debljine lima 22 mm je izrađen od čelika kvaliteta S275J2G3 (stara oznaka Č.0462). Maksimalni pritisak u njemu ispred turbinskog zatvarača je 2,5 MP. Na cevovodu se u kontinuitetu od završetka izgradnje i puštanja u rad sprovode geodetska merenja kada je cevovod prazan i neopterećen hidrostatičkim pritiskom i kada je cevovod pun. Pregledom i analizom dobijenih podataka o pomeranjima duž trase cevovoda utvrđeno je da od 2003-2004 godine postoje znatno veće razlike u pomeranjima za pun i prazan cevovod, nego u prethodnom periodu. U radu je izvršena analiza trenutnog stanja i ocena čvrstoče cevovoda kao celine na osnovu rezultata ispitivanja sučeonih zavarenih spojeva i ukrsnih masta metodama bez razaranja u zoni preloma na stacionaži - dužini cevovoda 1+263m (vizuelno ispitivanje, ispitivanje magnetnim česticama, ispitivanje penetrantima, ispitivanje ultrazvukom, radiografsko ispitivanje, metalografsko ispitivanje metodom replika).sr
dc.description.abstractHydro power plant Pirot, which was built in 1990, is an accumulation-derivative power plant, which consists of 2 above-ground vertical hydroelectric generating sets that contain Francis turbines with nominal power of 41,5 MW, manufactured in Czech Republic, a tunnel and a sunken pipeline with overall length of 2.030 m and diameter that ranges from 3.000 to 3.500 m. Pipes have been made of S275J2G3 steel. Pipe wall is 22 mm thick. Maximum pressure of 2.5 MPa occurs in front of the turbine cover. Geodetic measurements have been conducted permanently from the day the assembly was finished and pipeline was put into service, both when pipeline is empty and unloaded by hydrostatic pressure and when it is full. Analysis of obtained data regarding the movements along the pipeline route showed that from year 2003 there are significantly higher differences in movements comparing the situations when the pipeline is full and when it is empty in comparison with the previous period. This paper contains the analysis of current state and strength evaluation of the pipeline as a whole on the basis of results of non-destructive tests performed on the vital butt - welded joint in the curvature area at chainage 1+263 m (visual testing, magnetic particle testing, penetrant testing, ultrasonic testing, radiographic testing, metallographic replication testing).en
dc.publisherDUZS - Društvo za unapređivanje zavarivanja u Srbiji, Beograd
dc.rightsopenAccess
dc.sourceZavarivanje i zavarene konstrukcije
dc.subjecttehnologija sanacijesr
dc.subjectprslinasr
dc.subjecthidroelektranasr
dc.subjectčvrstoća cevovodasr
dc.subjectrepair technologyen
dc.subjectpipeline strengthen
dc.subjecthydroelectric generating planten
dc.subjectcracken
dc.titleAnaliza trenutnog stanja i ocena čvrstoće cevovoda na hidroelektrani Pirotsr
dc.titleAnalysis of current state and strength evaluation of the pipeline at hydro power plant 'Pirot'en
dc.typearticle
dc.rights.licenseARR
dc.citation.epage22
dc.citation.issue1
dc.citation.other63(1): 17-22
dc.citation.rankM52
dc.citation.spage17
dc.citation.volume63
dc.identifier.doi10.5937/zzk1801017A
dc.identifier.fulltexthttp://rims.institutims.rs/bitstream/id/195/336.pdf