In this paper, the main subject concerns comparing different techniques to prepare raw clay samples for energy dispersive X-ray fluorescence spectrometry (EDXRF). Three kinds of sample preparation procedures are examined,such as loose powder, pressed pellet, and fired pressed pellet. The fired pressed pellet approach was observed as a part of universal sample preparation for physic, mechanical, and instrumental analysis, which has not been previously tested as a solution in chemical analysis by the EDXRF method. The observed sample preparation techniques were compared by calculating the parameters of validation (recoveries, limit of detection-LOD, limit of quantification - LOQ, precision, and expanded uncertainties of measurements) of 11 elements (Si, Al, Fe, Ca, Mg, K, Na, Ti, P, Mn, and S) using 15 certified reference materials (CRMs). Calibration curves were created and evaluated using 30 reference materials (RM) for all three approaches. Results proved that the fired pressed pellet... is the most practical and precise approach for sample preparation of raw clays.
Keywords:
Chemical analysis / EDXRF / Sample preparation / Raw claysSource:
Talanta, 2022, 252Publisher:
- Elsevier
Funding / projects:
Collections
Institution/Community
Institut za ispitivanje materijalaTY - JOUR AU - Mijatović, Nevenka AU - Vasić, Milica AU - Miličić, Ljiljana AU - Radomirović, Milena AU - Radojević, Zagorka PY - 2022 UR - http://rims.institutims.rs/handle/123456789/427 AB - In this paper, the main subject concerns comparing different techniques to prepare raw clay samples for energy dispersive X-ray fluorescence spectrometry (EDXRF). Three kinds of sample preparation procedures are examined,such as loose powder, pressed pellet, and fired pressed pellet. The fired pressed pellet approach was observed as a part of universal sample preparation for physic, mechanical, and instrumental analysis, which has not been previously tested as a solution in chemical analysis by the EDXRF method. The observed sample preparation techniques were compared by calculating the parameters of validation (recoveries, limit of detection-LOD, limit of quantification - LOQ, precision, and expanded uncertainties of measurements) of 11 elements (Si, Al, Fe, Ca, Mg, K, Na, Ti, P, Mn, and S) using 15 certified reference materials (CRMs). Calibration curves were created and evaluated using 30 reference materials (RM) for all three approaches. Results proved that the fired pressed pellet is the most practical and precise approach for sample preparation of raw clays. PB - Elsevier T2 - Talanta T1 - Fired pressed pellet as a sample preparation technique of choice for an energy dispersive X-ray fluorescence analysis of raw clays VL - 252 DO - https://doi.org/10.1016/j.talanta.2022.123844 ER -
@article{ author = "Mijatović, Nevenka and Vasić, Milica and Miličić, Ljiljana and Radomirović, Milena and Radojević, Zagorka", year = "2022", abstract = "In this paper, the main subject concerns comparing different techniques to prepare raw clay samples for energy dispersive X-ray fluorescence spectrometry (EDXRF). Three kinds of sample preparation procedures are examined,such as loose powder, pressed pellet, and fired pressed pellet. The fired pressed pellet approach was observed as a part of universal sample preparation for physic, mechanical, and instrumental analysis, which has not been previously tested as a solution in chemical analysis by the EDXRF method. The observed sample preparation techniques were compared by calculating the parameters of validation (recoveries, limit of detection-LOD, limit of quantification - LOQ, precision, and expanded uncertainties of measurements) of 11 elements (Si, Al, Fe, Ca, Mg, K, Na, Ti, P, Mn, and S) using 15 certified reference materials (CRMs). Calibration curves were created and evaluated using 30 reference materials (RM) for all three approaches. Results proved that the fired pressed pellet is the most practical and precise approach for sample preparation of raw clays.", publisher = "Elsevier", journal = "Talanta", title = "Fired pressed pellet as a sample preparation technique of choice for an energy dispersive X-ray fluorescence analysis of raw clays", volume = "252", doi = "https://doi.org/10.1016/j.talanta.2022.123844" }
Mijatović, N., Vasić, M., Miličić, L., Radomirović, M.,& Radojević, Z.. (2022). Fired pressed pellet as a sample preparation technique of choice for an energy dispersive X-ray fluorescence analysis of raw clays. in Talanta Elsevier., 252. https://doi.org/https://doi.org/10.1016/j.talanta.2022.123844
Mijatović N, Vasić M, Miličić L, Radomirović M, Radojević Z. Fired pressed pellet as a sample preparation technique of choice for an energy dispersive X-ray fluorescence analysis of raw clays. in Talanta. 2022;252. doi:https://doi.org/10.1016/j.talanta.2022.123844 .
Mijatović, Nevenka, Vasić, Milica, Miličić, Ljiljana, Radomirović, Milena, Radojević, Zagorka, "Fired pressed pellet as a sample preparation technique of choice for an energy dispersive X-ray fluorescence analysis of raw clays" in Talanta, 252 (2022), https://doi.org/https://doi.org/10.1016/j.talanta.2022.123844 . .