Приказ основних података о документу
Procedure for correction of bearing capacity of piles examined by the Dynamic Load Test (DLT) according to the Static Load Test (SLT)
dc.creator | Ćosić, Mladen | |
dc.creator | Šušić, Nenad | |
dc.creator | Prica, Marko | |
dc.creator | Đoković, Ksenija | |
dc.date.accessioned | 2023-05-18T07:59:15Z | |
dc.date.available | 2023-05-18T07:59:15Z | |
dc.date.issued | 2023 | |
dc.identifier.issn | 1451-3749 | |
dc.identifier.uri | http://rims.institutims.rs/handle/123456789/493 | |
dc.description.abstract | The paper shows the comparative analysis of behavior and bearing capacity of piles examined using the Dynamic Load Test (DLT) according to Static Load Test (SLT) results. The pile testing methodology is based on the existing ASTM standards and experiences of the authors of the paper. The pile tests were carried out using counterweights, reactive system, dynamic testing equipment, hardware and software for SLT and DLT. The data obtained by testing were statis-tically processed, and also a regression analysis of the linear function was conducted, resulting in the creation of the model for the change of mobilized static bearing capacity from DLT according to SLT. In addition, a procedure for correcting the solution of mobilized static bearing capacity from DLT according to SLT, is made by observing provisions of standard EN 1997-1:2004, so the average deviation of solutions from DLT according to SLT is reduced. Apart from that, through iterations, the value of correlation factor ξ5 is determined, taking into consideration solutions presented by SLT and DLT of piles of the real structures. | sr |
dc.language.iso | en | sr |
dc.relation | info:eu-repo/grantAgreement/MESTD/inst-2020/200012/RS// | sr |
dc.rights | openAccess | sr |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.source | Structural Integrity and Life, Special Issue | sr |
dc.subject | pile | sr |
dc.subject | testing | sr |
dc.subject | SLT | sr |
dc.subject | DLT | sr |
dc.subject | bearing capacity | sr |
dc.subject | comparative analysis | sr |
dc.title | Procedure for correction of bearing capacity of piles examined by the Dynamic Load Test (DLT) according to the Static Load Test (SLT) | sr |
dc.type | article | sr |
dc.rights.license | BY-NC-ND | sr |
dc.citation.epage | 68 | |
dc.citation.spage | 53 | |
dc.citation.volume | 23 | |
dc.identifier.fulltext | http://rims.institutims.rs/bitstream/id/1201/bitstream_1201.pdf | |
dc.identifier.rcub | https://hdl.handle.net/21.15107/rcub_rims_493 | |
dc.type.version | publishedVersion | sr |