An augmented approach for the determination of the particle size effect on energy dispersive X-ray fluorescence analysis outcomes for alumina-based refractory materials

No Thumbnail
Authors
Mijatović, Nevenka
Vasić, Milica
Terzić, Anja
Radomirović, Milena
Miličić, Ljiljana
Article (Published version)
Metadata
Show full item record
Abstract
The chemical compositions of refractory materials, such as high-alumina concrete, bricks, and putty, were analyzed using an energy-dispersive X-ray spectrometer (EDXRF). An improved methodology for investigating the effect of particle size on the outcomes of EDXRF chemical analysis is presented. Eight independent refractory samples (refractory concrete, brick, and putty) were pulverized utilizing seven milling times (30, 60, 120, 180, 240, 300, and 360 s) and compared to non-pulverized samples. Thus, sixty-four refractory samples were obtained and analyzed using EDXRF. The method for measuring the fundamental EDXRF characteristics was then tested with ten certified reference materials. The acquired data were compared using inductively coupled plasma atomic emission spectrometry (ICP-OES). Univariate and multivariate statistics are used to evaluate EDXRF data. The particle size of the tested samples affected the z-scores of SiO2, Al2O3, Fe2O3, TiO2, CaO, MgO, Na2O, K2O, and P2O5 concent...ration measurements. Grinding times for refractory concrete, brick, and putty samples were determined in order to validate the robustness of the EDXRF technique and provide reliable chemical analyses. The ideal milling times for the samples studied ranged from 180 to 360 s, depending on the type of refractory material.

Source:
Spectrochimica Acta Part B: Atomic Spectroscopy, 2023, 209, 106796
Funding / projects:
  • Ministry of Education, Science and Technological Development, Republic of Serbia, Grant no. 200012 (Istitute of Material Testing of Serbia - IMS, Belgrade) (RS-200012)

DOI: 10.1016/j.sab.2023.106796

ISSN: 0584-8547

[ Google Scholar ]
URI
http://rims.institutims.rs/handle/123456789/577
Collections
  • Radovi istraživača / Researchers' publications
Institution/Community
Institut za ispitivanje materijala
TY  - JOUR
AU  - Mijatović, Nevenka
AU  - Vasić, Milica
AU  - Terzić, Anja
AU  - Radomirović, Milena
AU  - Miličić, Ljiljana
PY  - 2023
UR  - http://rims.institutims.rs/handle/123456789/577
AB  - The chemical compositions of refractory materials, such as high-alumina concrete, bricks, and putty, were analyzed using an energy-dispersive X-ray spectrometer (EDXRF). An improved methodology for investigating the effect of particle size on the outcomes of EDXRF chemical analysis is presented. Eight independent refractory samples (refractory concrete, brick, and putty) were pulverized utilizing seven milling times (30, 60, 120, 180, 240, 300, and 360 s) and compared to non-pulverized samples. Thus, sixty-four refractory samples were obtained and analyzed using EDXRF. The method for measuring the fundamental EDXRF characteristics was then tested with ten certified reference materials. The acquired data were compared using inductively coupled plasma atomic emission spectrometry (ICP-OES). Univariate and multivariate statistics are used to evaluate EDXRF data. The particle size of the tested samples affected the z-scores of SiO2, Al2O3, Fe2O3, TiO2, CaO, MgO, Na2O, K2O, and P2O5 concentration measurements. Grinding times for refractory concrete, brick, and putty samples were determined in order to validate the robustness of the EDXRF technique and provide reliable chemical analyses. The ideal milling times for the samples studied ranged from 180 to 360 s, depending on the type of refractory material.
T2  - Spectrochimica Acta Part B: Atomic Spectroscopy
T1  - An augmented approach for the determination of the particle size effect on energy dispersive X-ray fluorescence analysis outcomes for alumina-based refractory materials
IS  - 106796
VL  - 209
DO  - 10.1016/j.sab.2023.106796
ER  - 
@article{
author = "Mijatović, Nevenka and Vasić, Milica and Terzić, Anja and Radomirović, Milena and Miličić, Ljiljana",
year = "2023",
abstract = "The chemical compositions of refractory materials, such as high-alumina concrete, bricks, and putty, were analyzed using an energy-dispersive X-ray spectrometer (EDXRF). An improved methodology for investigating the effect of particle size on the outcomes of EDXRF chemical analysis is presented. Eight independent refractory samples (refractory concrete, brick, and putty) were pulverized utilizing seven milling times (30, 60, 120, 180, 240, 300, and 360 s) and compared to non-pulverized samples. Thus, sixty-four refractory samples were obtained and analyzed using EDXRF. The method for measuring the fundamental EDXRF characteristics was then tested with ten certified reference materials. The acquired data were compared using inductively coupled plasma atomic emission spectrometry (ICP-OES). Univariate and multivariate statistics are used to evaluate EDXRF data. The particle size of the tested samples affected the z-scores of SiO2, Al2O3, Fe2O3, TiO2, CaO, MgO, Na2O, K2O, and P2O5 concentration measurements. Grinding times for refractory concrete, brick, and putty samples were determined in order to validate the robustness of the EDXRF technique and provide reliable chemical analyses. The ideal milling times for the samples studied ranged from 180 to 360 s, depending on the type of refractory material.",
journal = "Spectrochimica Acta Part B: Atomic Spectroscopy",
title = "An augmented approach for the determination of the particle size effect on energy dispersive X-ray fluorescence analysis outcomes for alumina-based refractory materials",
number = "106796",
volume = "209",
doi = "10.1016/j.sab.2023.106796"
}
Mijatović, N., Vasić, M., Terzić, A., Radomirović, M.,& Miličić, L.. (2023). An augmented approach for the determination of the particle size effect on energy dispersive X-ray fluorescence analysis outcomes for alumina-based refractory materials. in Spectrochimica Acta Part B: Atomic Spectroscopy, 209(106796).
https://doi.org/10.1016/j.sab.2023.106796
Mijatović N, Vasić M, Terzić A, Radomirović M, Miličić L. An augmented approach for the determination of the particle size effect on energy dispersive X-ray fluorescence analysis outcomes for alumina-based refractory materials. in Spectrochimica Acta Part B: Atomic Spectroscopy. 2023;209(106796).
doi:10.1016/j.sab.2023.106796 .
Mijatović, Nevenka, Vasić, Milica, Terzić, Anja, Radomirović, Milena, Miličić, Ljiljana, "An augmented approach for the determination of the particle size effect on energy dispersive X-ray fluorescence analysis outcomes for alumina-based refractory materials" in Spectrochimica Acta Part B: Atomic Spectroscopy, 209, no. 106796 (2023),
https://doi.org/10.1016/j.sab.2023.106796 . .

DSpace software copyright © 2002-2015  DuraSpace
About RIMS | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About RIMS | Send Feedback

OpenAIRERCUB