dc.description.abstractThe paper presents typical examples of pile load tests with a specific analysis of results, whereby the test methodology relies on existing ASTM standards, own knowledge and experience. The pile tests were conducted using own equipment with licensed hardware and software for the Dynamic Load Test (DLT). The tests have shown the correct and problematic situations that arise when analyzing the bearing capacity of piles. Aspects of application of different equipment and testing methodologies in different situations are indicated. Also, the need to develop a plan for testing the load capacity of piles when it comes to large and significant structures was pointed out.sr
dc.language.isoensr
dc.publisherSavez građevinskih inženjera Srbije SGISsr
dc.relationinfo:eu-repo/grantAgreement/MESTD/inst-2020/200012/RS//sr
dc.rightsopenAccesssr
dc.rights.urihttps://creativecommons.org/licenses/by-sa/4.0/
dc.sourceEarthquake Engineering and Geotechnical Aspects of Civil Engineering, Vrnjačka Banja, Serbiasr
dc.subjectpilesr
dc.subjecttestssr
dc.subjectbearing capacitysr
dc.subjectDLTsr
dc.subjectsignal matchingsr
dc.titleSome Aspects of Pile Testing Using Dynamic Load Test (DLT)sr
dc.typeconferenceObjectsr
dc.rights.licenseBY-SAsr
dc.citation.epage299
dc.citation.spage289
dc.identifier.fulltexthttp://rims.institutims.rs/bitstream/id/1628/bitstream_1628.pdf