In present paper, rejection of the upper ring of the guiding apparatus (URGA) during
revitahzation of the A6 aggregates at HE Djerdap 1 has been presented. Rejection was
conducted after 37 years of exploitation based on the decisions made after testing, both
NDT and DT, and unsuccessful recovery using various welding technologies
Keywords:
upper ring of guiding apparatus / testing / lamellar tearingSource:
4th International conference “Civil Engineering – Science and Practice", 2012, 1255-1261Publisher:
- Univerzitet Crne Gore, Građevinski fakultet, Crna Gora
Funding / projects:
- Pressure equipment integrity under simultaneous effect of fatigue loading and temperature (RS-MESTD-Technological Development (TD or TR)-35011)
Collections
Institution/Community
Institut za ispitivanje materijalaTY - CONF AU - Aleksić, Vujadin AU - Kovačević, Zorica PY - 2012 UR - http://rims.institutims.rs/handle/123456789/800 AB - In present paper, rejection of the upper ring of the guiding apparatus (URGA) during revitahzation of the A6 aggregates at HE Djerdap 1 has been presented. Rejection was conducted after 37 years of exploitation based on the decisions made after testing, both NDT and DT, and unsuccessful recovery using various welding technologies PB - Univerzitet Crne Gore, Građevinski fakultet, Crna Gora C3 - 4th International conference “Civil Engineering – Science and Practice" T1 - Testing of upper ring of guiding apparatus during revitalization of A6 aggregate at HE Djerdap 1 EP - 1261 SP - 1255 UR - https://hdl.handle.net/21.15107/rcub_rims_800 ER -
@conference{ author = "Aleksić, Vujadin and Kovačević, Zorica", year = "2012", abstract = "In present paper, rejection of the upper ring of the guiding apparatus (URGA) during revitahzation of the A6 aggregates at HE Djerdap 1 has been presented. Rejection was conducted after 37 years of exploitation based on the decisions made after testing, both NDT and DT, and unsuccessful recovery using various welding technologies", publisher = "Univerzitet Crne Gore, Građevinski fakultet, Crna Gora", journal = "4th International conference “Civil Engineering – Science and Practice"", title = "Testing of upper ring of guiding apparatus during revitalization of A6 aggregate at HE Djerdap 1", pages = "1261-1255", url = "https://hdl.handle.net/21.15107/rcub_rims_800" }
Aleksić, V.,& Kovačević, Z.. (2012). Testing of upper ring of guiding apparatus during revitalization of A6 aggregate at HE Djerdap 1. in 4th International conference “Civil Engineering – Science and Practice" Univerzitet Crne Gore, Građevinski fakultet, Crna Gora., 1255-1261. https://hdl.handle.net/21.15107/rcub_rims_800
Aleksić V, Kovačević Z. Testing of upper ring of guiding apparatus during revitalization of A6 aggregate at HE Djerdap 1. in 4th International conference “Civil Engineering – Science and Practice". 2012;:1255-1261. https://hdl.handle.net/21.15107/rcub_rims_800 .
Aleksić, Vujadin, Kovačević, Zorica, "Testing of upper ring of guiding apparatus during revitalization of A6 aggregate at HE Djerdap 1" in 4th International conference “Civil Engineering – Science and Practice" (2012):1255-1261, https://hdl.handle.net/21.15107/rcub_rims_800 .