Претраживање
Приказ резултата 1-2 од 2
The comparative analysis of thermal behaviour of a different thicknesses walls made from autoclaved aerated concrete blocks exposed to fire
(Proceedings of the 19th International Symposium MASE, Ohrid, 2022, 2022)
In this paper a comparative analysis of thermal behavior of six partition walls with different
thicknesses were presented. The walls were dimensions 3000 mm x 3000 mm made from autoclaved
aerated concrete blocks with ...
Experimental analysis of fire resistance of clay hollow-brick masonry non-load bearing wall
(Proceeding of the 8th International Conference "Civil engineering-science and practice", Kolašin, 2022)
Testing the clay hollow-brick masonry non-load-bearing wall helps us to understand the behaviour of this type of wall during a fire. It is important to know the fire resistance of hollow brick walls so that we can prevent ...