Pretraživanje
Prikaz rezultata 1-10 od 11
Ispitivanje integriteta šipova - testiranje i analiza rezultata / Pile integrity testing: Testing and results analysis
(Društvo za ispitivanje i istraživanje materijala i konstrukcija Srbije, Beograd, 2019)
U radu su prikazani karakteristični primeri ispitivanja integriteta šipova sa analizom rezultata, pri čemu se metodologija ispitivanja oslanja na postojeće ASTM standarde, ali i na metodologiju ispitivanja prikazanu u ...
Ispitivanje integriteta i nosivosti šipova - metodologija i klasifikacija / Pile integrity and load testing: Methodology and classification
(Društvo za ispitivanje i istraživanje materijala i konstrukcija Srbije, Beograd, 2019)
U radu su prikazane metodologija i klasifikacija ispitivanja integriteta i nosivosti šipova, u saglasnosti sa važećim inostranim standardima, ali i sa sopstvenim definisanim segmentima unapređivanja standarda i sopstvenim ...
Čelici za armiranje betona / Steels for concrete reinforcement
(Institut za ispitivanje materijala, Beograd, 2005)
Ispitivanje čelika u građevinarstvu danas uključuje obimnu aktivnost koja nije na pravi način prikazana u domaćoj stručnoj literaturi. Ispitivanje je od velikog značaja u slučaju čelika za armiranje betona, jer može doći ...
Procedure for correction of bearing capacity of piles examined by the Dynamic Load Test (DLT) according to the Static Load Test (SLT)
(Structural Integrity and Life, Special Issue, 2023)
The paper shows the comparative analysis of behavior and bearing capacity of piles examined using the Dynamic Load Test (DLT) according to Static Load Test (SLT) results. The pile testing methodology is based on the existing ...
Fire resistance testing of fire doors
(8 th INTERNATIONAL SCIENTIFIC CONFERENCE SAFETY ENGINEERING CONFERENCE WITH INTERNATIONAL PARTICIPATION ON FIRE AND EXPLOSION PROTECTION Budva, Montenegro, BOOK OF PROCEEDINGS, 2022)
Fire-resistant doors are widely used as part of passive fire protection systems, preventing the spread of fire and smoke beyond the fire compartment. Fire resistance is usually determined through standard fire tests in ...
Pile capacity distribution analysis for SLT with reactive system
(GEOTECHNICAL ASPECTS OF CIVIL ENGINEERING AND EARTHQUAKE ENGINEERING - Vrnjačka Banja, 2023)
In the paper, the analysis of the bearing capacity of the pile and the redistribution of the
load on the pile toe and shaft was carried out. The tests were carried out by a static load test (SLT)
incrementally increasing ...
Comparative Analysis of Bearing Capacity of Piles Tested by Dynamic Load Test (DLT) and Pressuremeter Test (PMT)
(5th symposium of the Macedonian Association for Geotechnics, Ohrid, Macedonia, Proceedings, 2022)
The paper presents the comparative analysis of several piles for different pier locations of a bridge by employing in-situ deep foundations tests and in-situ soil tests. The focus of the paper is on the
presentation of ...
Analysis of Redistribution of the Pile Shaft-Base Load Using the Dynamic Load Test (DLT)
(Savez građevinskih inženjera Srbije SGIS, 2021)
The paper analyses transmission and redistribution of the load from the pile on the soil, with a special focus on these effects regarding the shaft and base of the pile. The test was conducted using the dynamic load test ...
Static-Dynamic Tests of Bearing Capacity of Wind Turbine Piles
(Comptes rendus de l’Académie bulgare des Sciences, 2022)
The paper presents the static load tests (SLT) and dynamic load tests (DLT) of the piles and numerical analyses of piles in interaction with the soil of wind turbines. Pile tests were conducted using the equipment with ...
Testing of metals in the function of determining the failure of turbine shaft – methodological approach
(Unversity of Banja Luka, Faculty of Mechanical Engineering, BiH, 2013)
This paper presents a methodological approach of testing of metals in the
function of determining the cause of failure and failure analysis of turbine shaft. The
analysis was conducted on the example of damage of the ...